Southgate Process Equipment is a top authorized distributor for Advantage Engineering.
If you are requiring a specific part or item please click here to request a quote or call us @ (770) 345-0010

 

Manufacturer of Chillers and Accessories

Advantage Engineering product catalog consist a large array of heat transfer products including:
For more information about Advantage adnd other products see the Advantage products brochures below. 

TEMPERATURE CONTROLLERS:

ADVANTAGE temperature controllers circulate fluid through a process application for HEATING or HEATING AND COOLING.
WATER UNITS, circulate water through the process and are used for applications where the required temperature ranges from 30° to 300°F. Water units use a pump to circulate water through the process, an electric immersion heater to add heat to the process and a cooling valve working with a plant water supply for cooling the process. Water units are portable and require a plant water supply source. Temperature controllers supply fluid temperatures from 30° to 500°F.
OIL UNITS, circulate oil through the process and are used for applications where the required temperature ranges from 100° to 500°F. Oil units use a pump to circulate high temperature heat transfer fluid through the process, an electric heater to add heat to the process and an optional heat exchanger with cooling water inlet control valve for cooling the process.

Central Water Chillers:

CENTRAL CHILLERS service multiple use points throughout the plant. Central chillers are stationary, and require a circulating system to distribute water to the process. Central chillers are offered in capacities from 20 to 500 tons. ADVANTAGE central chillers are offered as MODULES and PACKAGES. A module is a stand-alone chiller unit that requires a pump tank station to distribute the chilled water. A package is a self-contained unit with the chiller and pump tank station on a single platform.
Water-Cooled WPT modules (5-180 tons) are stationary units designed to provide chilling capacity to new or exsiting central chilled water systems. These units require an external pumping systems to circulate chilled water to process and for condensing water.
Air-Cooled APT modules (5-180 tons) are stationary units designed to provide chilling capacity to new or existing central chilled water systems. These units require an external pumping system to circulate chilled water to process and for condensing water. The air-cooled condenser is located outside of the facility.
OACS systems are designed to be installed outside using no valuable indoor floor space and are a complete package including water reservoir and pumping system. The system is fully factory tested before shipment and requires minimal installation.
OACS systems are available with 1 or 2 independnet refrigeration zone for energy efficient capacity staging and to provide partial or full redundancy.

Titan systems combine multiple refrigeration zones for redundancy & capacity staging with a large capacity reservoir and pumping system. The refrigeration system, reservoir and pumping system remain indoors while the remote air-cooled condenser is located outside the production facility.
Titan systems are available with 1, 2 or 3 independent refrigeration zones for energy efficiently capacity staging and to provide partial or full redundancy.

Portable Chillers

PORTABLE CHILLERS supply temperatures between 20° to 70°F, are self contained units and use a refrigerant system to chill water. The chilled water is stored in a reservoir and supplied to the process using a circulating pump. Custom designed microprocessor instrumentation control the unit’s operation. Portable chillers can service single or multiple process cooling points, and are designed to be moved between process applications as needed.
Purpose Built Air-Cooled Portable Chillers for EDM Machines.
Cooling Applications provides these Features:
• Indoor Units
• Air-Cooled Condenser
• 20°F – 80°F Fluid Temperatures
• Non Ozone Depleting Refrigerant
Advantage’s Maximum Series Portable Chillers are refrigeration units coupled with an
integral fluid circulation system that range in cooling capacity from 1/4 to 40 tons. These units are used to cool fluids to support industrial process cooling applications requiring a fluid temperature range from 20°F to 80°F.

Evaporative Cooling Towers

Advantage Power Tower Series Cooling Towers:
Made of durable UV protected fiberglass with a counter air flow design.
  • Capacities from 45 to 540 tons.
  • Long lasting with the non rusting, UV protected reinforced fiberglass shell.
  • Simple Maintenance with only 1 moving part that requires only periodic lubrication.
  • Easy to Install with clearly labeled process connection and a steel base for easy rigging and mounting.

Pump Tank Stations

POLYETHYLENE RESERVOIRS, TOUGH TANK, are a patented hybrid design that creates a structurally sound cylindrical reservoir that provides total corrosion resistance. Polyethylene reservoirs are used in both tower and chiller systems. Each system is customized by our design engineers to include the proper reservoir size, flow, pump pressure and desired options.
 
METAL RESERVOIRS are built of epoxy coated mild steel or stainless steel sheets, welded and reinforced by angular tank banding.
 
PUMPING SYSTEMS are part of the Pump Tank Stations. Heavy-duty centrifugal pumps
specifically selected for the application provide the required flow and pressure to each use point in the system. Systems are configured with process pump or process and recirculating pump with optional standby. Systems can be equipped with full electrical starting, monitoring and diagnostic components including variable speed drive systems that maintain constant fluid flow and pressure.
Advantage Engineering and their products please email us at sales@southgatepe.com or call us (770) 345-0010.
We look forward to helping you with all your Advantage product needs.

REQUEST A QUOTE

  • Hidden
  • This field is for validation purposes and should be left unchanged.